mg, mcg and IU: The Units in Peptide Research and How They Convert
Key Takeaways
- Milligrams and micrograms are SI mass units a factor of 1,000 apart: 1 mg = 1,000 mcg, and mcg is the safer spelling of µg [1] [3].
- An International Unit (IU) measures biological activity against a WHO International Standard, so it converts to mass only with the factor published for that one substance: 3.0 IU per mg for somatropin, about 26 to 29 IU per mg for human insulin, 40 IU per mcg for vitamin D, and no fixed mass factor at all for hCG [6] [11] [16] [18].
- Syringe units are volume marks, not IU, and any step from mg or IU to mL needs the solution's concentration [14].
- An International Unit is the unitage WHO assigns to an International Biological Standard: a physical reference preparation, established by the Expert Committee on Biological Standardization, against which the biological activity of that one substance is measured [4] [5].
On this page
What are mg, mcg and IU?
Milligrams (mg) and micrograms (mcg, also written µg) are decimal fractions of the gram, defined by the SI prefixes milli (10⁻³) and micro (10⁻⁶) [1] [2]. They measure mass, and converting between them is only a matter of moving the decimal point three places.
An International Unit (IU) is different in kind. It measures biological activity, not mass: WHO assigns the unitage to a physical International Standard for one substance, and every laboratory’s measurement of that substance is compared with it [4] [5]. Because each standard is its own definition, the IU of somatropin, the IU of insulin and the IU of vitamin D are unrelated quantities, and none of them converts to mg without a published factor for that substance [6] [11] [18].
Published peptide research uses all three. Vial contents and analytical standards are stated in mg, study amounts are usually reported per kilogram in mg/kg or µg/kg, blood concentrations in ng/mL, and a few biologicals with a long bioassay history (growth hormone, insulin, hCG) still carry IU [9] [17].
SI mass prefixes: g, mg, mcg and ng
The SI prefixes step by powers of ten; the ones that matter for peptide quantities step by a thousand [1] [2].
| Unit | Symbol | Prefix | Factor | In grams | Equivalents |
|---|---|---|---|---|---|
| gram | g | — | 10⁰ | 1 g | 1,000 mg [1] |
| milligram | mg | milli | 10⁻³ | 0.001 g | 1,000 mcg [1] |
| microgram | mcg or µg | micro | 10⁻⁶ | 0.000001 g | 1,000 ng; 0.001 mg [1] |
| nanogram | ng | nano | 10⁻⁹ | 0.000000001 g | 0.001 mcg [1] |
So the conversions are:
- mg to mcg: multiply by 1,000. 0.25 mg = 250 mcg; 2 mg = 2,000 mcg.
- mcg to mg: divide by 1,000. 500 mcg = 0.5 mg; 50 mcg = 0.05 mg.
- g to mg: multiply by 1,000. 0.005 g = 5 mg.
NIST notes that the symbols for submultiple prefixes are all lowercase, which is why mg, mcg and ng never take a capital [1]. A capital M means mega (10⁶), so “Mg” would be a megagram, a tonne [1]. The mcg, mg and IU converter does the three-place shift either way.
µg vs mcg: one microgram, two spellings
The SI symbol for micro is the Greek letter µ, so the formal symbol for microgram is µg [1] [2].
The Institute for Safe Medication Practices lists µg on its List of Error-Prone Abbreviations because a handwritten or badly rendered µ is mistaken for m, which turns the quantity into mg, a thousand times larger; its recommended practice is to write mcg [3]. The same list recommends writing “units” rather than IU, because IU has been misread as IV or as the number 10, and warns against trailing zeros after a decimal point, where 1.0 mg is read as 10 mg if the point is missed [3].
Research papers and WHO documents keep µg, because they are typeset rather than handwritten; the NIBSC instructions for the somatropin standard, for example, report growth hormone measurements in µg/L [6]. Both spellings therefore turn up in the literature, and they mean the same quantity.
mg vs mcg
A milligram is the larger unit: 1 mg = 1,000 mcg, so a quantity in mcg always has a number a thousand times bigger than the same quantity in mg [1]. The two units tend to appear in different places. The mass of peptide in a research vial or an analytical standard is quoted in mg; the WHO somatropin standard, for instance, is value-assigned at 1.95 mg per ampoule [6]. Amounts given to animals in published studies are mostly in µg/kg or mg/kg of body weight, and circulating concentrations are reported in ng/mL, as in the pharmacokinetic sections of approved somatropin labels [9].
Converting between them is arithmetic, not judgment. A 2 mg vial holds 2,000 mcg; 250 mcg is 0.25 mg; 10 mcg is 0.01 mg. The same shift applies to concentrations: 2 mg/mL is 2,000 mcg/mL. Errors come from the decimal point rather than the arithmetic, which is the basis for ISMP’s advice to avoid trailing zeros and to write a leading zero before a bare decimal [3].
What is an International Unit (IU)?
An International Unit is the unitage WHO assigns to an International Biological Standard [5]. WHO’s Expert Committee on Biological Standardization establishes these standards after multi-laboratory collaborative studies; the standard is a physical preparation, usually a freeze-dried ampoule, and it provides the unique physical basis for the definition of the IU of biological or immunological activity for that substance [4] [5]. The first standard for a substance receives an assigned value, and later standards are calibrated against the earlier one so that the unit stays continuous [7] [8].
Three consequences follow. First, an IU is defined per substance: the 3.0 IU per mg of somatropin says nothing about insulin [6] [11]. Second, a mass equivalent exists only when a standard has been characterized in both ways. The somatropin standards were, which is why a fixed factor can be quoted; the current hCG standard is assigned in IU only, with its mass content described as approximate and not to be used as a formal mass value [6] [16].
Third, the unit can depend on the assay: the 6th International Standard for hCG carries 159 IU per ampoule for bioassay and 186 IU per ampoule for immunoassay, from the same material [16].
The trend in standardization is away from IU for well-characterized recombinant proteins. The somatropin standard is value-assigned in mass, with the IU described as historical, and the 2nd International Standard for human insulin was assigned 9.19 mg per ampoule by mass-balance methods because IU “no longer reflects the international transition to a mass assigned molecule” [6] [12]. The ISMP list’s preference for writing “units” instead of IU is a separate, safety-driven point about handwriting [3].
IU to mg: documented factors and where they come from
Each factor below comes from the WHO standard or an approved label for that one substance, and applies to nothing else.
| Substance | Documented relationship | Defined by | Sources |
|---|---|---|---|
| Somatropin (recombinant human growth hormone) | 3.0 IU per mg of somatropin, so 1 mg = 3 IU and 6 mg = 18 IU | WHO 1st International Standard 88/624 (1994) and 2nd International Standard 98/574 (2001); FDA labels print both units, for example 6 mg (18 IU), 12 mg (36 IU) and 24 mg (72 IU) cartridges, and 3.33 mg/kg paired with 10 IU/kg | [6] [7] [8] [9] [10] |
| Insulin, human | One IU is the activity in 0.03846 mg of the 83/500 standard (26.0 IU per mg of that material). The 2nd International Standard quotes 1 IU = 0.0347 mg of pure insulin (about 28.8 IU per mg). An EMA-approved label states 1 IU = 0.035 mg and 100 IU/mL = 3.5 mg/mL | WHO International Standard 83/500; 2nd International Standard 11/212; EMA summary of product characteristics | [11] [12] [13] |
| Chorionic gonadotropin (hCG) | No fixed mass factor. The 6th International Standard is assigned 159 IU per ampoule by bioassay and 186 IU per ampoule by immunoassay; each ampoule was filled from about 20 µg of hCG, a figure the standard says is approximate and not a formal mass value. U.S. labels state USP units, standardized by biological assay | WHO 6th International Standard 18/244 (2020); FDA-approved label | [16] [17] |
| Vitamin D (non-peptide example) | 1 mcg of cholecalciferol = 40 IU; 1 IU = 0.025 mcg. FDA requires mcg on Nutrition and Supplement Facts labels, with IU optional in parentheses | FDA guidance for industry (2019), citing the historical bioassay definition | [18] |
With a factor in hand the arithmetic is one line each way:
- mg = IU ÷ (IU per mg). For somatropin at 3.0 IU per mg: 18 IU ÷ 3 = 6 mg [6].
- IU = mg × (IU per mg). For somatropin: 2 mg × 3 = 6 IU [6].
- mcg = mg × 1,000 after either step [1].
For human insulin the three published figures differ at the second decimal because they describe different materials: hydrated crystals of one standard, pure anhydrous insulin, and an approved product’s rounding [11] [12] [13]. That is the general lesson of the table: the IU-to-mg factor belongs to a specific standard or label, and the certificate of analysis or label for the material in hand is the document that states which one applies. The converter’s IU fields open only once a factor is entered for that reason.
Syringe units are volume marks, not IU
Insulin syringes are graduated in “units” rather than millilitres. A U-100 syringe is made for insulin at 100 units per mL, and the Humulin R U-100 carton carries both statements: “100 units per mL (U-100)” and “Use only with a U-100 syringe” [14]. Each unit mark is therefore one hundredth of a millilitre, 0.01 mL, and 50 marks is 0.5 mL whatever liquid the barrel holds.
The marks coincide with international units only for the one solution the scale was drawn for. The Humulin R U-500 label makes the point in reverse: a U-100 syringe “is made to measure U-100 insulin”, a U-500 solution measured on it produces a five-fold error, and on the dedicated U-500 syringe each line measures 5 units of U-500 insulin [15]. For a reconstituted peptide the marks are nothing but volume, and the mass in that volume depends on the concentration, which is the subject of the next section and of the syringe units guide.
IU to mL and mg to mL need a concentration
Neither mg nor IU converts to millilitres on its own. A millilitre is a volume; how much substance it contains depends on how much was dissolved in how much liquid. Two lines of arithmetic cover every case:
- Concentration (mg/mL) = mass in the vial (mg) ÷ volume of diluent added (mL).
- Volume (mL) = amount (mg) ÷ concentration (mg/mL).
Worked example, with round numbers. A vial containing 2 mg of peptide is dissolved in 1 mL of diluent. The concentration is 2 ÷ 1 = 2 mg/mL, which is 2,000 mcg/mL [1]. The volume that contains 200 mcg is 200 ÷ 2,000 = 0.1 mL; on a U-100 scale, 0.1 mL falls on the 10-unit mark [14]. Dissolving the same 2 mg in 2 mL instead gives 1 mg/mL, and the volume holding 200 mcg doubles to 0.2 mL. The mass never changed; the volume did.
For a material labelled in IU the same two lines apply with IU in place of mg, and if a mass is also needed the substance’s published factor converts the result [6]. The peptide calculator runs this arithmetic for single and blend vials and shows the U-100 reading; the converter handles the IU step once a factor is entered.
What published sources don’t establish
- A universal IU-to-mg rate. WHO defines the IU per substance, and the current hCG standard is assigned in IU with no formal mass value, so “IU to mg” has no answer until the substance and its standard are named [5] [16].
- A single factor even within one substance. The three published figures for human insulin (0.03846, 0.0347 and 0.035 mg per IU) describe different materials and purposes, and the hCG standard’s IU differs between bioassay and immunoassay [11] [12] [13] [16]. The Humatrope label itself pairs 6 mg with 18 IU in its description and 0.1 mg/kg with 0.27 IU/kg in its pharmacokinetics section [9].
- That a vial’s stated mass equals active peptide. The somatropin standard’s 1.95 mg per ampoule is total somatropin protein including higher-molecular-weight forms and related impurities, and NIBSC instructs laboratories to correct it for the monomer percentage measured by their own method [6]. A certificate of analysis for a research material is the only document that states that material’s content.
- Any amount for use. The conversions above describe measurement. The approved labels and WHO documents cited here concern specific licensed products and reference materials, and nothing in them transfers to an unlicensed research peptide.
Related research pages
For research and educational purposes only. Not medical advice. PB Peptide does not provide medical, dosing or treatment guidance. Study data on this page describes what researchers did and observed; it is not a recommendation for any use.
Frequently asked questions
How many mcg are in a mg?
1,000. The SI prefix milli means one thousandth (10⁻³) and micro means one millionth (10⁻⁶), so one milligram holds 1,000 micrograms and one gram holds 1,000 milligrams [1] [2].
Is mg or mcg bigger?
A milligram is bigger. One mg is 1,000 mcg, so 0.25 mg is 250 mcg and 5 mg is 5,000 mcg [1].
Is mcg the same as µg?
Yes. Both abbreviate microgram; µ is the SI prefix symbol for micro [1]. The Institute for Safe Medication Practices lists µg as error-prone because it is mistaken for mg, and recommends writing mcg [3].
What is an IU?
An International Unit is the unitage WHO assigns to an International Biological Standard: a physical reference preparation, established by the Expert Committee on Biological Standardization, against which the biological activity of that one substance is measured [4] [5]. It is not a unit of mass, and the IU of one substance has no relationship to the IU of another.
How many IU are in a mg?
It depends entirely on the substance. For somatropin the WHO International Standard defines 3.0 IU per mg [6]. For human insulin, one IU is the activity in 0.03846 mg of the 83/500 standard (26.0 IU per mg), and the current standard quotes 1 IU = 0.0347 mg for pure insulin [11] [12]. For vitamin D, 1 mcg = 40 IU, which is 40,000 IU per mg [18]. For hCG no fixed mass factor exists; its standard is assigned in IU only [16].
Are the units on an insulin syringe the same as IU?
No. A U-100 syringe is graduated for insulin made at 100 units per mL, so each unit mark is a volume of 0.01 mL [14]. Those marks equal IU of insulin only when the syringe holds U-100 insulin; for any other solution they are simply hundredths of a millilitre [15].
Sources
- National Institute of Standards and Technology Metric (SI) Prefixes. NIST Office of Weights and Measures.
- Bureau International des Poids et Mesures SI prefixes. BIPM.
- Institute for Safe Medication Practices ISMP List of Error-Prone Abbreviations and Symbols (2024 edition). ISMP / ECRI, 2024.
- World Health Organization Providing International biological reference standards. WHO.
- WHO Expert Committee on Biological Standardization Recommendations for the preparation, characterization and establishment of international and other biological reference standards (revised 2004). WHO Technical Report Series No. 932, Annex 2. WHO, 2006.
- National Institute for Biological Standards and Control WHO International Standard: Somatropin (Recombinant DNA-Derived Human Growth Hormone), NIBSC code 98/574. Instructions for use, version 6.0. NIBSC, 2025.
- Bristow AF et al. The First International Standard for Somatropin: report of an international collaborative study. Growth Regulation, 1995. PMID 7580864.
- Bristow AF, Jespersen AM The Second International Standard for somatropin (recombinant DNA-derived human growth hormone): preparation and calibration in an international collaborative study. Biologicals, 2001. PMID 11580214. DOI 10.1006/biol.2001.0281.
- Eli Lilly and Company HUMATROPE (somatropin) for injection: prescribing information, revised 11/2025. DailyMed, U.S. National Library of Medicine, 2025.
- EMD Serono, Inc. SEROSTIM (somatropin) for injection: prescribing information, revised 9/2026. DailyMed, U.S. National Library of Medicine, 2026.
- National Institute for Biological Standards and Control WHO International Standard: Insulin, Human, NIBSC code 83/500. Instructions for use, version 4.0. NIBSC, 2010.
- National Institute for Biological Standards and Control WHO International Standard: 2nd International Standard for insulin, human, NIBSC code 11/212. Instructions for use, version 2.0. NIBSC, 2025.
- European Medicines Agency Insuman: EPAR product information (summary of product characteristics). EMA, 2026.
- Eli Lilly and Company HUMULIN R (insulin human) injection, 100 units per mL: prescribing information, revised 6/2023. DailyMed, U.S. National Library of Medicine, 2023.
- Eli Lilly and Company HUMULIN R U-500 (insulin human) injection: prescribing information, revised 7/2026. DailyMed, U.S. National Library of Medicine, 2026.
- National Institute for Biological Standards and Control WHO International Standard: 6th International Standard for Chorionic Gonadotrophin, human, NIBSC code 18/244. Instructions for use, version 4.0. NIBSC, 2025.
- Fresenius Kabi USA, LLC Chorionic Gonadotropin for injection, USP, 10,000 USP units per vial: prescribing information. DailyMed, U.S. National Library of Medicine.
- U.S. Food and Drug Administration Converting Units of Measure for Folate, Niacin, and Vitamins A, D, and E on the Nutrition and Supplement Facts Labels: Guidance for Industry. FDA Center for Food Safety and Applied Nutrition, 2019.
Page history
- November 19, 2026: Drafted from NIST and BIPM prefix tables, the 2024 ISMP error-prone abbreviations list, WHO and NIBSC documents on International Standards for somatropin, insulin and hCG, the FDA labels that print both mg and IU, and FDA's 2019 unit-conversion guidance.